Severity
Moderate
CPSC recall · Reported February 11, 2005
A gas leak can occur if there is a crack in the gas valve body near the inlet pipe connection. A build-up of gas in the burner compartment of the unit could occur, which could be …
Trane and American Standard, divisions of American Standard Inc., of Tyler, Texas recalled The recalled units include 2- through 5-ton Trane and American Standard heating and air c… - a moderate-severity action.
CPSC, American Standard Companies Announce Recall of Gas-Electric Heating/Cooling Units was recalled by Trane and American Standard, divisions of American Standard Inc., of Tyler, Texas in February 11, 2005. Reason: A gas leak can occur if there is a crack in the gas valve body near the inlet pipe connection. A build-up of …. Remedy: Consumers with recalled units are being contacted by the independent dealers that install…. Verify recall #05104 with the CPSC before acting.
The recall
Trane and American Standard, divisions of American Standard Inc., of Tyler, Texas issued this moderate-severity CPSC recall-A gas leak can occur if there is a crack in the gas valve body near the inlet pipe connection. A build-up of ….
Sourced from official CPSC enforcement records. Verify recall #05104 with the agency before acting. Full product description, hazard, remedy, and related recalls are below.
This CPSC action (record #05104) was formally reported on February 11, 2005. It is classified under Moderate severity, with a current status of Active. Trane and American Standard, divisions of American Standard Inc., of Tyler, Texas is listed as the recalling firm. Federal records list the affected scope as About 18,200.
The documented reason for this recall is: A gas leak can occur if there is a crack in the gas valve body near the inlet pipe connection. A build-up of gas in the burner compartment of the unit could occur, which could be ignited by an internal spark. Distribution information was not included in the agency filing, so consumers should assume broad potential exposure until the firm publishes point-of-sale details. The remedy documented by the agency is: Consumers with recalled units are being contacted by the independent dealers that installed them. Consumers who think they have recalled units and have not yet been contacted, should call their insta… - consumers holding this product should act on that instruction rather than relying on general guidance.
Within the same product category the archive holds 6 closely related recalls, 6 from CPSC - clustering in a narrow category often points to a systemic quality-control or supplier issue rather than a one-off defect. Always verify the recall number against the official agency record before acting.
Where this recall sits in its category - 3,056 household products recalls on record
Of 101,704 recalls in the database, 24,878 are high severity, 72,426 moderate, and 4,400 low. This recall is classified moderate severity.
Counts reflect market size and reporting activity, not inherent danger, we do not rank products by risk from raw recall volume.
Severity
Moderate
Affected scope
About 18,200
Related Recalls
6
6 from same agency
The recalled units include 2- through 5-ton Trane and American Standard heating and air conditioning packaged units. Affected units are combination gas heat and air conditioning systems installed outdoors only. Gas furnaces installed indoors are not included in this recall. The units have identification plates displaying the model number; serial number; and the year, month and day of manufacture. The plate is located on one end of the unit. The first four digits of all serial numbers indicate the year, fiscal week and day of manufacture. The recall includes: - All units with model numbers beginning with YCP or YCX and having serial numbers beginning with 3383 through 4475; - All units with model number beginning with YCY or YCZ and having serial numbers beginning with 4282 through 4475.
A gas leak can occur if there is a crack in the gas valve body near the inlet pipe connection. A build-up of gas in the burner compartment of the unit could occur, which could be ignited by an internal spark.
Consumers with recalled units are being contacted by the independent dealers that installed them. Consumers who think they have recalled units and have not yet been contacted, should call their installer for more information. Using their model and serial numbers, consumers also can visit the firms' Web sites to confirm if their unit is included in the recall. Consumers with recalled units should contact their installer to arrange for a free inspection.
| Attribute | Value |
|---|---|
| Agency | U.S. Consumer Product Safety Commission |
| Severity class | Moderate |
| Status | Active |
| Recall number | 05104 |
| Date reported | February 11, 2005 |
| Date initiated | February 11, 2005 |
| Recalling firm | Trane and American Standard, divisions of American Standard Inc., of Tyler, Texas |
| Affected scope | About 18,200 |
| Distribution | Not disclosed |
| Official source | CPSC notice → |
Profile values are sourced directly from the official CPSC enforcement record. Source: U.S. Consumer Product Safety Commission.
What to do with this recall
Consumers with recalled units are being contacted by the independent dealers that installed them. Consumers who think they have r…
This page summarizes the official CPSC record for research and awareness; it is not legal, medical, or safety advice. Verify with the issuing agency before acting.
Other recalls in the same product category, useful for spotting patterns across the same defect class or manufacturer.
Cooper Lighting, LLC, of Peachtree City, Georgia · 2026-07-02
· 2026-07-02
· 2026-07-02
· 2026-06-25
· 2026-06-25
Compare this recall with Cooper Lighting Recalls Metalux Optimized High Bay LED Ligh… →
Every figure on PlainRecalls is rendered directly from official FDA, CPSC and NHTSA recall records, no number is typed in by an editor. This recall: CPSC, reported February 11, 2005. Severity classes follow each agency's own taxonomy (FDA Class I/II/III; CPSC and NHTSA by hazard type), and related-recall context is computed across the full archive. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of July 2026.