Siemens Recalls Circuit Breakers Due to Fire Hazard
The recalled circuit breakers have a spring clip that can break during normal use, leading to a loss of force to maintain a proper electrical connection in the panelboard. This ca…
The CPSC recalled This recall involves Siemens and Murray 15 through 50 AMP single and double pole circuit ….
Siemens Recalls Circuit Breakers Due to Fire Hazard was recalled and listed by the CPSC in September 23, 2010. Reason: The recalled circuit breakers have a spring clip that can break during normal use, leading to a loss of force…. Remedy: Consumers should immediately contact Siemens for a free inspection by an electrician and …. Verify recall #10354 with the CPSC before acting.
The recall
issued this CPSC recall-The recalled circuit breakers have a spring clip that can break during normal use, leading to a loss of force….
- None
- agency class
- September 23, 2010
- reported
Sourced from official CPSC enforcement records. Verify recall #10354 with the agency before acting. Full product description, hazard, remedy, and related recalls are below.
Recall Insight
This recall's affected scope, documented in the Recall Profile below, stays within a single-region or limited-distribution footprint. Distribution information was not included in the agency filing, so consumers should assume broad potential exposure until the firm publishes point-of-sale details. Consumers holding this product should act on the agency's documented remedy above rather than relying on general guidance.
Within the same product category the archive holds 6 closely related recalls, 6 from CPSC - clustering in a narrow category often points to a systemic quality-control or supplier issue rather than a one-off defect. Always verify the recall number against the official agency record before acting.
Household Products recalls over time
Where this recall sits in its category - 3,089 household products recalls on record
Product description
This recall involves Siemens and Murray 15 through 50 AMP single and double pole circuit breakers, load centers (circuit breakers that come with an electrical panel), and meter combos (contain a load center and a meter socket). "Siemens" or "Murray," date codes 0610 or 0710 and the catalog number are printed on a label on the side of the circuit breakers. Date codes between June 2010 through August 2010 are stamped on the inside of the metal box of the load centers and meter combos. The catalog number for the load centers and meter combos is printed on a label inside the metal box door and on the packaging. Product Date Codes Catalog Numbers Circuit Breakers 0610, 0710 Q115, Q120, Q130, Q215, Q230, Q250, MP115, MP115U, MP120, MP130, MP215, MP230, MP230U, MP250 Load Centers Jun 23 2010 - Aug 25 2010 G2020B1100CP, G3030B1100CP, G4040B1200CUSGP, LC4040B1200P, G3040B1200CP, G3040L1200CP, G4040B1200CP, G3030B1150CP, W3040B1200CP, G1624L1125CP, W4040B1200CP Meter Combo Jun 23 2010 - Aug 25 2010 JA2040B1200S
Reason for recall
The recalled circuit breakers have a spring clip that can break during normal use, leading to a loss of force to maintain a proper electrical connection in the panelboard. This can lead to excessive temperature, arcing or thermal damage at the connection point, and damage to the panelboard's electrical insulation and can result in a fire, property damage, or personal injury.
Remedy, what to do
Consumers should immediately contact Siemens for a free inspection by an electrician and a free replacement product.
Recall Profile
| Attribute | Value |
|---|---|
| Agency | U.S. Consumer Product Safety Commission |
| Severity class | Not classified by agency |
| Status | Active |
| Recall number | 10354 |
| Date reported | September 23, 2010 |
| Date initiated | September 23, 2010 |
| Recalling firm | Not disclosed |
| Affected scope | About 2.2 million |
| Distribution | Not disclosed |
| Official source | CPSC notice → |
Profile values are sourced directly from the official CPSC enforcement record. Source: U.S. Consumer Product Safety Commission.
What to do with this recall
Consumers should immediately contact Siemens for a free inspection by an electrician and a free replacement product.
- Check the recall number (10354) and product description against the item you own. Search the archive
- Confirm the current status and remedy on the official CPSC notice before acting. CPSC notice
- Follow the documented remedy (refund, replacement, repair, or disposal) rather than general advice. What to do next
This page summarizes the official CPSC record for research and awareness; it is not legal, medical, or safety advice. Verify with the issuing agency before acting.
Frequently Asked Questions
What product was recalled? ▼
Why was this product recalled? ▼
What should consumers do? ▼
Which agency issued this recall? ▼
How do I report an injury from a recalled product? ▼
Nationwide recalls with similar severity or category timing
Consumer-product notices outside this firm and state, matched by severity timing and product category.
Similar severity · nearest report date
Same archive severity grade, closest by report date among other firms and states.
Similar Household Products · nearest report date
Same product category, closest by report date among other firms and states (deduped against the severity set).
Compare this recall with CCM Hockey U.S. Recalls FMHVR Hybrid Visors and ACCHVR Repl… → · All Household Products recalls
Methodology · Corrections · Archive as of August 2026