Severity
Moderate
CPSC recall · Reported November 23, 2010
The models have a grounding system and trigger switch that could cause ground wire abrasion and/or ground connector failure posing a shock hazard. In addition, the switch trigger …
The CPSC recalled Bosch 1/2 inch 2-Speed Hammer Drill with model number HD19-2, HD19-2D, HD19-2L and 1/2 in… - a moderate-severity action.
Robert Bosch Tool Corp. Recalls Bosch Hammer Drills Due to Electrical Shock Hazard was recalled and listed by the CPSC in November 23, 2010. Reason: The models have a grounding system and trigger switch that could cause ground wire abrasion and/or ground con…. Remedy: Consumers should immediately stop using the hammer drill and return hammer drill to Rober…. Verify recall #11051 with the CPSC before acting.
The recall
issued this moderate-severity CPSC recall-The models have a grounding system and trigger switch that could cause ground wire abrasion and/or ground con….
Sourced from official CPSC enforcement records. Verify recall #11051 with the agency before acting. Full product description, hazard, remedy, and related recalls are below.
This CPSC action (record #11051) was formally reported on November 23, 2010. It is classified under Moderate severity, with a current status of Active. The recalling firm is not specified in the federal record. Federal records list the affected scope as About 20,000 units.
The documented reason for this recall is: The models have a grounding system and trigger switch that could cause ground wire abrasion and/or ground connector failure posing a shock hazard. In addition, the switch trigger could become stuck in the "on" position … Distribution information was not included in the agency filing, so consumers should assume broad potential exposure until the firm publishes point-of-sale details. The remedy documented by the agency is: Consumers should immediately stop using the hammer drill and return hammer drill to Robert Bosch Tool Corporation for repair. - consumers holding this product should act on that instruction rather than relying on general guidance.
Within the same product category the archive holds 6 closely related recalls, 6 from CPSC - clustering in a narrow category often points to a systemic quality-control or supplier issue rather than a one-off defect. Always verify the recall number against the official agency record before acting.
Where this recall sits in its category - 3,056 household products recalls on record
Of 101,704 recalls in the database, 24,878 are high severity, 72,426 moderate, and 4,400 low. This recall is classified moderate severity.
Counts reflect market size and reporting activity, not inherent danger, we do not rank products by risk from raw recall volume.
Severity
Moderate
Affected scope
About 20,000 units
Related Recalls
6
6 from same agency
Bosch 1/2 inch 2-Speed Hammer Drill with model number HD19-2, HD19-2D, HD19-2L and 1/2 inch 2-Speed Hammer Drills with model number HD 21-2 are included in this recall. "BOSCH" is printed in red lettering on the side of the drills.
The models have a grounding system and trigger switch that could cause ground wire abrasion and/or ground connector failure posing a shock hazard. In addition, the switch trigger could become stuck in the "on" position posing an injury hazard to the user.
Consumers should immediately stop using the hammer drill and return hammer drill to Robert Bosch Tool Corporation for repair.
| Attribute | Value |
|---|---|
| Agency | U.S. Consumer Product Safety Commission |
| Severity class | Moderate |
| Status | Active |
| Recall number | 11051 |
| Date reported | November 23, 2010 |
| Date initiated | November 23, 2010 |
| Recalling firm | Not disclosed |
| Affected scope | About 20,000 units |
| Distribution | Not disclosed |
| Official source | CPSC notice → |
Profile values are sourced directly from the official CPSC enforcement record. Source: U.S. Consumer Product Safety Commission.
What to do with this recall
Consumers should immediately stop using the hammer drill and return hammer drill to Robert Bosch Tool Corporation for repair.
This page summarizes the official CPSC record for research and awareness; it is not legal, medical, or safety advice. Verify with the issuing agency before acting.
Other recalls in the same product category, useful for spotting patterns across the same defect class or manufacturer.
Cooper Lighting, LLC, of Peachtree City, Georgia · 2026-07-02
· 2026-07-02
· 2026-07-02
· 2026-06-25
· 2026-06-25
Compare this recall with Cooper Lighting Recalls Metalux Optimized High Bay LED Ligh… →
Every figure on PlainRecalls is rendered directly from official FDA, CPSC and NHTSA recall records, no number is typed in by an editor. This recall: CPSC, reported November 23, 2010. Severity classes follow each agency's own taxonomy (FDA Class I/II/III; CPSC and NHTSA by hazard type), and related-recall context is computed across the full archive. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of July 2026.