Severity
Moderate
Fu San Machinery Co. Ltd., of Taiwan issued this CPSC recall on December 11, 2012. Classified as Moderate severity. Approximately About 163,000 units are affected. The recall was issued because: The valves can crack and cause gas to leak. This poses fire and explosion hazards.. This recall notice is sourced from official CPSC enforcement records. Below you will find the complete product description, hazard information, remedy instructions, and related recalls from the same manufacturer or product category.
This CPSC action (record #13064) was formally reported on December 11, 2012. It is classified under Moderate severity, with a current status of Active. Fu San Machinery Co. Ltd., of Taiwan is listed as the recalling firm. Federal records indicate About 163,000 units are affected, a scale large enough to require multi-state distribution tracking.
The documented reason for this recall is: The valves can crack and cause gas to leak. This poses fire and explosion hazards. Distribution information was not included in the agency filing, so consumers should assume broad potential exposure until the firm publishes point-of-sale details. The remedy documented by the agency is: Consumers should turn off the gas supply until a replacement gas valve has been professionally installed. Consumers should contact Danville Sales which, on behalf of Fu San Machinery, will provide co… — consumers holding this product should act on that instruction rather than relying on general guidance.
To put this record in context, PlainRecalls indexes 83,949 recalls across the FDA, CPSC, NHTSA and USDA FSIS going back to 1995. Within the same product category, the database holds 6 closely related recalls, of which 6 were also issued by CPSC. That clustering is a signal — repeated actions in a narrow category often indicate a systemic quality-control issue, a supplier-wide contamination, or a design defect that has propagated across product lines. This recall is roughly 14 years old; older recalls can remain relevant because many units enter resale, rental, and secondary-market channels where the original warning never reaches the end user. Always cross-check the recall number against the official agency page before relying on any summary.
Severity
Moderate
Units Affected
About 163,000
Related Recalls
6
6 from same agency
This recall involves seven brands of sweat and threaded, low lead ball valves used in flammable gas piping systems used in commercial or residential settings. They are brass shut-off valves assembled with pipe lines of ¾ inch and 1 inch and have a date code 1103 through 1112, in YYMM format, where YY is the year and MM is the month. The date code is located under the valve handle. The pipe size is marked on the body of the valve. Fu San's logo and the "O" marking designated for low lead valves are marked on the valves' neck under where the handle assembles. The word "Taiwan" appears on the handle as a country of origin marking. The valves were sold under the following brand names and model numbers: Brand Name Model Number Valve Dimensions/Sweat or Threaded Valves Aqualine BBV-075-LF ¾ inch/Threaded BBV-075S-LF ¾ inch/Sweat BBV-100-LF 1 inch/Threaded BBV-100S-LF 1 inch/Sweat AY McDonald 72032S ¾ inch/Sweat 72032T ¾ inch/Threaded FNW FNWX410AF ¾ inch/Threaded FNWX410AG 1 inch/Threaded FNWX411F ¾ inch/Sweat FNWX411G 1 inch/Sweat Hodes Co. 40-642 1 inch/Threaded 40-662 1 inch /Threaded 40-677 ¾ inch/Sweat 40-687 ¾ inch/Sweat 40-678 1 inch/Sweat 40-688 1 inch/Sweat Legend T1002NL 1 inch/Threaded Leonard Valve 83503 ¾ inch/Sweat 83504 1 inch/Sweat 83538 ¾ inch/Threaded 83539 1 inch/Threaded Mueller 107-844NL ¾ inch/Sweat
The valves can crack and cause gas to leak. This poses fire and explosion hazards.
Consumers should turn off the gas supply until a replacement gas valve has been professionally installed. Consumers should contact Danville Sales which, on behalf of Fu San Machinery, will provide compensation of $300 to reimburse customers for costs incurred to remove and return the valve and for purchasing and installing a replacement valve. The affected valve should be returned to the Danville Sales Office for Fu San Machinery with a photo depicting the valve in the gas line before removal and showing the date code on the valve, along with the address and details of the location where the valve was installed. The requested information, the recalled valve, and the consumer name and address should be sent to the address in the Consumer Contact paragraph. Upon receipt, Fu San will reimburse customers in the amount of $300.
| Attribute | Value |
|---|---|
| Agency | U.S. Consumer Product Safety Commission |
| Severity class | Moderate |
| Status | Active |
| Recall number | 13064 |
| Date reported | December 11, 2012 |
| Date initiated | December 11, 2012 |
| Recalling firm | Fu San Machinery Co. Ltd., of Taiwan |
| Units affected | About 163,000 |
| Distribution | Not disclosed |
Profile values are sourced directly from the official CPSC enforcement record. Source: U.S. Consumer Product Safety Commission.
Learn how the US recall system works and how to protect yourself and your household.
How the US Recall System Works
The three federal agencies, how recalls are initiated, and what happens next.
Understanding Recall Severity Classes
What Class I, II, and III mean and which recalls demand immediate action.
What to Do When a Product Is Recalled
Verify, claim your remedy, report injuries, and navigate the process.
How to Check If Your Products Are Recalled
Step-by-step guide to checking food, products, medications, and vehicles.
Recalled Products in Your Home
A room-by-room household audit guide for active recalls.
Most Recalled Product Categories
Rankings of highest-recall categories from FDA, CPSC, and NHTSA.
Product recalls are issued when a manufacturer, distributor, or federal agency determines that a product poses a safety risk to consumers. This recall is classified as moderate severity, indicating the product may cause temporary or medically reversible health consequences. Across PlainRecalls, we track 83,000+ recalls from FDA, CPSC, and NHTSA to help consumers stay informed and act quickly when safety issues arise.
Explore related product safety and public health data from federal sources.
Food Safety Inspections
FDA and state food facility inspection results — violations, enforcement actions, and compliance history for food manufacturers and processors.
PlainFoodSafe →
Ingredient Safety Data
FDA food additive and ingredient safety database — regulatory status, usage limits, and safety assessments for thousands of ingredients.
PlainIngredients →
Nutrition Data
USDA nutrition facts for 2M+ food items — calories, macros, vitamins, and ingredient analysis to verify what you consume.
GetFoodFacts →
Drug Safety Information
FDA drug data for 680+ medications — interactions, alternatives, side effects, and safety information for recalled and active drugs.
PlainMeds →
Product Injury Data
CPSC emergency room injury data for 838 product categories — 7.3M NEISS records tracking real-world consumer product injuries.
PlainSafety →
Recall Checker
Search our database of 83K+ recalls by product name, brand, or recall number across all agencies.
Check Now →
Recall Radar
Live feed of the latest recalls across FDA, CPSC, NHTSA, and USDA — filter by agency and severity.
View Radar →
Other recalls in the same product category — useful for spotting patterns across the same defect class or manufacturer.
Electrolux Consumer Products, Inc., of Charlotte, North Carolina · 2026-03-19
· 2026-03-19
· 2026-03-19
· 2026-02-26
Jiangsu Ever-Tie Lighting Co., Ltd, of China · 2026-02-26
Compare this recall with Electrolux Group Recalls Frigidaire Gas Ranges Due to Burn … →
Data as of 2025. Source: FDA, CPSC, NHTSA, USDA FSIS federal recall databases.
Recall information is sourced from official federal agency databases. Always verify recall details with the issuing agency for the most current status. This information is for research and awareness purposes only.
Read our methodology — how this data is sourced, computed, and verified.
Source: Federal recall agencies (FDA, CPSC, NHTSA, USDA FSIS) Aggregated multi-agency recall feeds · 2024 Recall data normalized across federal agency feeds; severity classifications follow each agency's own taxonomy (FDA Class I/II/III; CPSC, NHTSA, USDA FSIS).