PlainRecalls
ModerateActive

CPSC recall · Reported February 20, 2014

Sterling Rope Company Recalls Sewn Cords Due to Fall Hazard

Sewn cords break at a lower weight than published weight values, posing a fall hazard.

Recall #
14108
Affected scope
About 9,200 in the U.S. and 480 in Canada
Verify with CPSC →
View my saved recalls

Sterling Rope Company, Inc., of Biddeford, Maine recalled This recall involves four models of Sterling Rope's sewn cords which include the 8mm Azte… — a moderate-severity action.

Sterling Rope Company Recalls Sewn Cords Due to Fall Hazard was recalled by Sterling Rope Company, Inc., of Biddeford, Maine in February 20, 2014. Reason: Sewn cords break at a lower weight than published weight values, posing a fall hazard.. Remedy: Consumers should discontinue use of the product and contact Sterling Rope for a free repl…. Verify recall #14108 with the CPSC before acting.

The recall

Sterling Rope Company, Inc., of Biddeford, Maine issued this moderate-severity CPSC recall — Sewn cords break at a lower weight than published weight values, posing a fall hazard..

Moderate
severity level
February 20, 2014
reported

Sourced from official CPSC enforcement records. Verify recall #14108 with the agency before acting. Full product description, hazard, remedy, and related recalls are below.

Recall Insight

This CPSC action (record #14108) was formally reported on February 20, 2014. It is classified under Moderate severity, with a current status of Active. Sterling Rope Company, Inc., of Biddeford, Maine is listed as the recalling firm. Federal records list the affected scope as About 9,200 in the U.S. and 480 in Canada.

The documented reason for this recall is: Sewn cords break at a lower weight than published weight values, posing a fall hazard. Distribution information was not included in the agency filing, so consumers should assume broad potential exposure until the firm publishes point-of-sale details. The remedy documented by the agency is: Consumers should discontinue use of the product and contact Sterling Rope for a free replacement. The item may also be returned to an authorized Sterling dealer that will coordinate the free replacem… — consumers holding this product should act on that instruction rather than relying on general guidance.

Within the same product category the archive holds 6 closely related recalls — clustering in a narrow category often points to a systemic quality-control or supplier issue rather than a one-off defect. Always verify the recall number against the official agency record before acting.

Vehicles recalls over time

Where this recall sits in its category — 9,301 vehicles recalls on record

02004006008001,000 20052008201120142017202020232026 109

Where this recall sits in the database

Severity2366872097High severity (most serious)Moderate severityLow severity
Where this recall sits in the database

Of 100,165 recalls in the database, 23,668 are high severity, 72,097 moderate, and 4,400 low. This recall is classified moderate severity.

Counts reflect market size and reporting activity, not inherent danger — we do not rank products by risk from raw recall volume.

Severity

Moderate

Affected scope

About 9,200 in the U.S. and 480 in Canada

Related Recalls

6

0 from same agency

Product description

This recall involves four models of Sterling Rope's sewn cords which include the 8mm Aztek (AZ) Sewn Bound Loop Prusik, Aztek (AZ) Elite 8mm Edge Restraint, 8mm PER Sewn Eye and the 8mm Accessory Cord Sewn Eye. Sterling Rope products have the production lot number in two places. The product number and lot number are printed on the barcode label attached to the Care, Use and Retirement document, which comes with every product. The lot number is also printed on the shrink tube label on the sewn portion of the Prusik, edge restraint or sewn eye. Please see www.sterlingrope.com for a full list of lot numbers affected by this recall. All ropes except for the solid black products have a wrapping dotted line design around the rope. Specific recalled colors are listed next to each recalled product description. 8mm Bound Loop Prusiks Product Number Description SC080320116 8mm AZ Bound Loop Prusik Short Teal Green x 16" SC080321116 8mm AZ BLP cord Short Tan x 16" SC080320322 8mm AZ Sewn BLP Cord Long Purple x 22" SC080320422 8mm AZ Sewn BLP Cord Long Black x 22" SC080320622 8mm AZ Sewn BLP Cord Long Blue x 22" SC080320716 8mm AZ Sewn BLP cord Short Orange x 16" SC080320816 8mm AZ Sewn BLP cord Short Red x 16" CUSTOMSC 8mm Tan Bound Loop Prusik by 24" CUSTOMSC 8mm Blue Bound Loop Prusik by 30" Aztek Elite 8mm Edge Restraints Product Number Description SC080NY04600 AZ Elite Tactical Edge Restraint x 50' SC080NY06600 AZ Elite 8mm Edge Restraint Blue 50' Sewn End SC080NY09600 AZ Elite 8mm Edge Restraint Yellow x 50' 8mm PER Sewn Eye Product Number Description PER0804407SE 8mm PER Black Safety Glo x 22ft with Sewn Eye CUSTOMSC 8mm PER Black Safety Glo with Sewn Eye CUSTOMSC 8mm PER Orange With Sewn Eye CUSTOMSC 8mm PER Yellow With Sewn Eye 8mm Accessory Cord Sewn Eye Product Number Description CUSTOMSC 8mm Black Accessory Cord With Sewn Eye CUSTOMSC 8mm Blue Accessory Cord With Sewn Eye CUSTOMSC 8mm Yellow Accessory Cord With Sewn Eye

Reason for recall

Sewn cords break at a lower weight than published weight values, posing a fall hazard.

Remedy — what to do

Consumers should discontinue use of the product and contact Sterling Rope for a free replacement. The item may also be returned to an authorized Sterling dealer that will coordinate the free replacement for you.

Recall Profile

Structured summary of the CPSC recall record
Attribute Value
Agency U.S. Consumer Product Safety Commission
Severity class Moderate
Status Active
Recall number 14108
Date reported February 20, 2014
Date initiated February 20, 2014
Recalling firm Sterling Rope Company, Inc., of Biddeford, Maine
Affected scope About 9,200 in the U.S. and 480 in Canada
Distribution Not disclosed
Official source CPSC notice →

Profile values are sourced directly from the official CPSC enforcement record. Source: U.S. Consumer Product Safety Commission.

What to do with this recall

Consumers should discontinue use of the product and contact Sterling Rope for a free replacement. The item may also be returned t…

  • Check the recall number (14108) and product description against the item you own. Search the archive
  • Confirm the current status and remedy on the official CPSC notice before acting. CPSC notice
  • Follow the documented remedy (refund, replacement, repair, or disposal) rather than general advice. What to do next

This page summarizes the official CPSC record for research and awareness; it is not legal, medical, or safety advice. Verify with the issuing agency before acting.

Frequently Asked Questions

What product was recalled?
This recall involves four models of Sterling Rope's sewn cords which include the 8mm Aztek (AZ) Sewn Bound Loop Prusik, Aztek (AZ) Elite 8mm Edge Restraint, 8mm PER Sewn Eye and the 8mm Accessory Cord Sewn Eye. Sterling Rope products have the production lot number in two places. The product number and lot number are printed on the barcode label attached to the Care, Use and Retirement document, which comes with every product. The lot number is also printed on the shrink tube label on the sewn portion of the Prusik, edge restraint or sewn eye. Please see www.sterlingrope.com for a full list of lot numbers affected by this recall. All ropes except for the solid black products have a wrapping dotted line design around the rope. Specific recalled colors are listed next to each recalled product description. 8mm Bound Loop Prusiks Product Number Description SC080320116 8mm AZ Bound Loop Prusik Short Teal Green x 16" SC080321116 8mm AZ BLP cord Short Tan x 16" SC080320322 8mm AZ Sewn BLP Cord Long Purple x 22" SC080320422 8mm AZ Sewn BLP Cord Long Black x 22" SC080320622 8mm AZ Sewn BLP Cord Long Blue x 22" SC080320716 8mm AZ Sewn BLP cord Short Orange x 16" SC080320816 8mm AZ Sewn BLP cord Short Red x 16" CUSTOMSC 8mm Tan Bound Loop Prusik by 24" CUSTOMSC 8mm Blue Bound Loop Prusik by 30" Aztek Elite 8mm Edge Restraints Product Number Description SC080NY04600 AZ Elite Tactical Edge Restraint x 50' SC080NY06600 AZ Elite 8mm Edge Restraint Blue 50' Sewn End SC080NY09600 AZ Elite 8mm Edge Restraint Yellow x 50' 8mm PER Sewn Eye Product Number Description PER0804407SE 8mm PER Black Safety Glo x 22ft with Sewn Eye CUSTOMSC 8mm PER Black Safety Glo with Sewn Eye CUSTOMSC 8mm PER Orange With Sewn Eye CUSTOMSC 8mm PER Yellow With Sewn Eye 8mm Accessory Cord Sewn Eye Product Number Description CUSTOMSC 8mm Black Accessory Cord With Sewn Eye CUSTOMSC 8mm Blue Accessory Cord With Sewn Eye CUSTOMSC 8mm Yellow Accessory Cord With Sewn Eye. Recalled by Sterling Rope Company, Inc., of Biddeford, Maine. Units affected: About 9,200 in the U.S. and 480 in Canada.
Why was this product recalled?
Sewn cords break at a lower weight than published weight values, posing a fall hazard.
What should consumers do?
Consumers should discontinue use of the product and contact Sterling Rope for a free replacement. The item may also be returned to an authorized Sterling dealer that will coordinate the free replacement for you.
Which agency issued this recall?
This recall was issued by the CPSC on February 20, 2014. Severity: Moderate. Recall number: 14108.
How do I check if my product is affected by a recall?
Check the product description and recall number (14108) against your product. Visit the official CPSC website for the most current information. You can also use our Recall Checker tool to search by product name or brand.
How do I report an injury from a recalled product?
Report injuries to the issuing agency: CPSC at SaferProducts.gov, NHTSA at nhtsa.gov/report-a-safety-problem, or FDA via MedWatch. Document the product (photos, model/serial numbers, purchase receipts) and seek medical attention. Injury reports help agencies track hazard patterns and may strengthen enforcement actions.

Nearby Recalls in This Category

Other recalls in the same product category — useful for spotting patterns across the same defect class or manufacturer.

Compare this recall with Gas-X, Simethicone 125 mg/ ANTIGAS, 120 SoftGels, Distribut… →

Data Sources

Source: FDA, CPSC, and NHTSA federal recall databases. This recall: CPSC, reported February 20, 2014.

  • Source: FDA — Food and Drug Administration, openFDA Enforcement API (food, drug, and medical device recalls)
  • Source: CPSC — Consumer Product Safety Commission Recalls API (consumer product recalls and hazards)
  • Source: NHTSA — National Highway Traffic Safety Administration Recalls API (vehicle safety recalls)

Recall information is sourced from official federal agency databases. Always verify recall details with the issuing agency for the most current status. This information is for research and awareness purposes only.

Every figure on PlainRecalls is rendered directly from official FDA, CPSC and NHTSA recall records — no number is typed in by an editor. Severity classes follow each agency's own taxonomy (FDA Class I/II/III; CPSC and NHTSA by hazard type), and related-recall context is computed across the full archive. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of June 2026.