Severity
Critical
NHTSA recall · Reported September 22, 2017
PACCAR Incorporated (PACCAR) is recalling certain 2016 Peterbilt 220, 320, 325, 330, 337, 348, 365, 367, 382, 384, 386, 389, 389G, 567, 579 and 587 trucks and Kenworth K170, T170,…
Kenworth,Peterbilt recalled PACCAR Incorporated (PACCAR) is recalling certain 2016 Peterbilt 220, 320, 325, 330, 337,… - a critical-severity action.
KENWORTH,PETERBILT 2016: STEERING:LINKAGES:TIE ROD ASSEMBLY was recalled by Kenworth,Peterbilt in September 22, 2017. Reason: PACCAR Incorporated (PACCAR) is recalling certain 2016 Peterbilt 220, 320, 325, 330, 337, 348, 365, 367, 382,…. Remedy: PACCAR will notify owners, and dealers will inspect the torque of the castellated nut and…. Verify recall #17V593000 with the NHTSA before acting.
The recall
Kenworth,Peterbilt issued this critical-severity NHTSA recall-PACCAR Incorporated (PACCAR) is recalling certain 2016 Peterbilt 220, 320, 325, 330, 337, 348, 365, 367, 382,….
Sourced from official NHTSA enforcement records. Verify recall #17V593000 with the agency before acting. Full product description, hazard, remedy, and related recalls are below.
This NHTSA action (record #17V593000) was formally reported on September 22, 2017. It is classified under Critical severity, with a current status of Active. Kenworth,Peterbilt is listed as the recalling firm. The number of affected units is not disclosed in the agency filing, which is common for drug and food recalls where lot-level tracking supersedes unit counts.
The documented reason for this recall is: PACCAR Incorporated (PACCAR) is recalling certain 2016 Peterbilt 220, 320, 325, 330, 337, 348, 365, 367, 382, 384, 386, 389, 389G, 567, 579 and 587 trucks and Kenworth K170, T170, T270, T370, T440, T470,T660, T680, T800… The specific hazard cited in the filing is: If the tie rod loosens, it may disconnect from the steering knuckle, causing a complete loss of steering and increasing the risk of a crash.. Distribution data in the federal record shows the product reached: United States. Distribution scope directly affects the consumer exposure window and determines whether a recall remains regional or escalates into a nationwide advisory. The remedy documented by the agency is: PACCAR will notify owners, and dealers will inspect the torque of the castellated nut and tie rod, tightening it as necessary. If the tie rod stud and knuckle on units cannot be sufficiently torqued… - consumers holding this product should act on that instruction rather than relying on general guidance.
Within the same product category the archive holds 6 closely related recalls - clustering in a narrow category often points to a systemic quality-control or supplier issue rather than a one-off defect. Always verify the recall number against the official agency record before acting.
Where this recall sits in its category - 7,642 vehicles recalls on record
Of 101,704 recalls in the database, 24,878 are high severity, 72,426 moderate, and 4,400 low. This recall is classified high severity.
Counts reflect market size and reporting activity, not inherent danger, we do not rank products by risk from raw recall volume.
Severity
Critical
Affected scope
Unknown
Related Recalls
6
0 from same agency
PACCAR Incorporated (PACCAR) is recalling certain 2016 Peterbilt 220, 320, 325, 330, 337, 348, 365, 367, 382, 384, 386, 389, 389G, 567, 579 and 587 trucks and Kenworth K170, T170, T270, T370, T440, T470,T660, T680, T800, T880, and W900 trucks equipped with certain Spicer D or E series steer axles. The castellated nut on the steer axles may not be properly torqued, allowing the tie rod to loosen.
PACCAR Incorporated (PACCAR) is recalling certain 2016 Peterbilt 220, 320, 325, 330, 337, 348, 365, 367, 382, 384, 386, 389, 389G, 567, 579 and 587 trucks and Kenworth K170, T170, T270, T370, T440, T470,T660, T680, T800, T880, and W900 trucks equipped with certain Spicer D or E series steer axles. The castellated nut on the steer axles may not be properly torqued, allowing the tie rod to loosen.
If the tie rod loosens, it may disconnect from the steering knuckle, causing a complete loss of steering and increasing the risk of a crash.
PACCAR will notify owners, and dealers will inspect the torque of the castellated nut and tie rod, tightening it as necessary. If the tie rod stud and knuckle on units cannot be sufficiently torqued, the dealer will replace the knuckle and tie rod end assembly, free of charge. The recall began on November 13, 2017. Owners may contact Peterbilt customer service at 1-940-591-4000 or Kenworth customer service at 1-425-828-5000. PACCAR's number for this recall is P817-C.
| Attribute | Value |
|---|---|
| Agency | National Highway Traffic Safety Administration |
| Severity class | Critical |
| Status | Active |
| Recall number | 17V593000 |
| Date reported | September 22, 2017 |
| Date initiated | September 22, 2017 |
| Recalling firm | Kenworth,Peterbilt |
| Affected scope | Not disclosed |
| Distribution | United States |
| Official source | NHTSA notice → |
Profile values are sourced directly from the official NHTSA enforcement record. Source: National Highway Traffic Safety Administration.
What to do with this recall
PACCAR will notify owners, and dealers will inspect the torque of the castellated nut and tie rod, tightening it as necessary. I…
This page summarizes the official NHTSA record for research and awareness; it is not legal, medical, or safety advice. Verify with the issuing agency before acting.
Other recalls in the same product category, useful for spotting patterns across the same defect class or manufacturer.
Yongkang Ruihe Metal Products Co. Ltd., of China · 2026-06-25
· 2026-06-18
CooCooBaby, of China · 2026-06-18
Kawasaki Motors Manufacturing Corp., U.S.A., of Lincoln, Nebraska · 2026-06-11
· 2026-06-11
Compare this recall with Yamazuki Recalls Youth All-Terrain Vehicles (ATVs) Due to R… →
Every figure on PlainRecalls is rendered directly from official FDA, CPSC and NHTSA recall records, no number is typed in by an editor. This recall: NHTSA, reported September 22, 2017. Severity classes follow each agency's own taxonomy (FDA Class I/II/III; CPSC and NHTSA by hazard type), and related-recall context is computed across the full archive. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of July 2026.