Severity
Moderate
CPSC recall · Reported June 12, 2018
The downlights power supply connectors can have incorrect wiring, posing an electric shock hazard to the user.
The CPSC recalled This recall involves the Ketra D3 recessed downlights produced between November 4, 2016 a… - a moderate-severity action.
Ketra Recalls to Inspect Recessed Downlights Due to Electrical Shock Hazard was recalled and listed by the CPSC in June 12, 2018. Reason: The downlights power supply connectors can have incorrect wiring, posing an electric shock hazard to the user.. Remedy: Consumers should immediately stop using the recalled downlights and contact the firm to s…. Verify recall #18175 with the CPSC before acting.
The recall
issued this moderate-severity CPSC recall-The downlights power supply connectors can have incorrect wiring, posing an electric shock hazard to the user..
Sourced from official CPSC enforcement records. Verify recall #18175 with the agency before acting. Full product description, hazard, remedy, and related recalls are below.
This CPSC action (record #18175) was formally reported on June 12, 2018. It is classified under Moderate severity, with a current status of Active. The recalling firm is not specified in the federal record. Federal records list the affected scope as About 3,400.
The documented reason for this recall is: The downlights power supply connectors can have incorrect wiring, posing an electric shock hazard to the user. Distribution information was not included in the agency filing, so consumers should assume broad potential exposure until the firm publishes point-of-sale details. The remedy documented by the agency is: Consumers should immediately stop using the recalled downlights and contact the firm to schedule a free inspection and, if needed, repair by a technician. Consumers should not try to inspect or repai… - consumers holding this product should act on that instruction rather than relying on general guidance.
Within the same product category the archive holds 6 closely related recalls, 6 from CPSC - clustering in a narrow category often points to a systemic quality-control or supplier issue rather than a one-off defect. Always verify the recall number against the official agency record before acting.
Where this recall sits in its category - 609 electronics recalls on record
Of 101,704 recalls in the database, 24,878 are high severity, 72,426 moderate, and 4,400 low. This recall is classified moderate severity.
Counts reflect market size and reporting activity, not inherent danger, we do not rank products by risk from raw recall volume.
Severity
Moderate
Affected scope
About 3,400
Related Recalls
6
6 from same agency
This recall involves the Ketra D3 recessed downlights produced between November 4, 2016 and March 14, 2018. The date code is located on a sticker attached to each unit and is in the format KWWYY representing WW-work week and YY-year of manufacture. Only downlights with date codes between K4816 and K1118 are included in this recall. The Ketra D3 downlight is typically installed behind a ceiling and the light generated by the LED illuminates the space below. The light fixture enclosure measures 18.5 inches by 10 inches by 4 inches. The downlight is dark gray and black and weighs approximately eight pounds.
The downlights power supply connectors can have incorrect wiring, posing an electric shock hazard to the user.
Consumers should immediately stop using the recalled downlights and contact the firm to schedule a free inspection and, if needed, repair by a technician. Consumers should not try to inspect or repair the units themselves. Warnings and instructions must be followed to disconnect power prior to servicing, removing or replacing the recalled products.
| Attribute | Value |
|---|---|
| Agency | U.S. Consumer Product Safety Commission |
| Severity class | Moderate |
| Status | Active |
| Recall number | 18175 |
| Date reported | June 12, 2018 |
| Date initiated | June 12, 2018 |
| Recalling firm | Not disclosed |
| Affected scope | About 3,400 |
| Distribution | Not disclosed |
| Official source | CPSC notice → |
Profile values are sourced directly from the official CPSC enforcement record. Source: U.S. Consumer Product Safety Commission.
What to do with this recall
Consumers should immediately stop using the recalled downlights and contact the firm to schedule a free inspection and, if needed…
This page summarizes the official CPSC record for research and awareness; it is not legal, medical, or safety advice. Verify with the issuing agency before acting.
Other recalls in the same product category, useful for spotting patterns across the same defect class or manufacturer.
Shenzhen Bopu Product Design Co., Ltd., dba POPOOO, of China · 2026-07-02
· 2026-06-25
· 2026-06-25
· 2026-06-25
School Specialty, LLC, of Greenville, Wisconsin · 2026-06-11
Compare this recall with Projecting LED Finger Light Toys Recalled Due to Risk of Se… →
Every figure on PlainRecalls is rendered directly from official FDA, CPSC and NHTSA recall records, no number is typed in by an editor. This recall: CPSC, reported June 12, 2018. Severity classes follow each agency's own taxonomy (FDA Class I/II/III; CPSC and NHTSA by hazard type), and related-recall context is computed across the full archive. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of July 2026.