Severity
Moderate
FDA Devices recall · Reported August 20, 2014
Integra LifeSciences is recalling the Integra NewPort MIS System because there is a possibility that components from the demonstration set may have been mixed with the NewPort MIS…
Integra LifeSciences Corp. recalled Integra NewPort MIS System Model No. NWPIMP (NewPort Implant Tray w/ Component… - a moderate-severity action.
Integra NewPort MIS System Model No. NWPIMP (NewPort Implant Tray w/ Component… was recalled by Integra LifeSciences Corp. in August 20, 2014. Reason: Integra LifeSciences is recalling the Integra NewPort MIS System because there is a possibility that componen…. Check the official notice for the remedy. Verify recall #Z-2182-2014 with the FDA Devices before acting.
The recall
Integra LifeSciences Corp. issued this moderate-severity FDA Devices recall-Integra LifeSciences is recalling the Integra NewPort MIS System because there is a possibility that componen….
Sourced from official FDA Devices enforcement records. Verify recall #Z-2182-2014 with the agency before acting. Full product description, hazard, remedy, and related recalls are below.
This FDA Devices action (record #Z-2182-2014) was formally reported on August 20, 2014, with the manufacturer initiating the action on June 27, 2014. It is classified under Moderate severity (Class II), with a current status of Terminated. Integra LifeSciences Corp. is listed as the recalling firm, operating out of Plainsboro, NJ. Federal records list the affected scope as 4 units.
The documented reason for this recall is: Integra LifeSciences is recalling the Integra NewPort MIS System because there is a possibility that components from the demonstration set may have been mixed with the NewPort MIS pedicle screw system components used in… Distribution data in the federal record shows the product reached: US Distribution in TX only.. Distribution scope directly affects the consumer exposure window and determines whether a recall remains regional or escalates into a nationwide advisory.
Within the same product category the archive holds 6 closely related recalls, 3 from FDA Devices - clustering in a narrow category often points to a systemic quality-control or supplier issue rather than a one-off defect. Always verify the recall number against the official agency record before acting.
Where this recall sits in its category - 40,322 medical devices recalls on record
Of 101,704 recalls in the database, 24,878 are high severity, 72,426 moderate, and 4,400 low. This recall is classified moderate severity.
Counts reflect market size and reporting activity, not inherent danger, we do not rank products by risk from raw recall volume.
Severity
Moderate
Affected scope
4 units
Related Recalls
6
3 from same agency
Integra NewPort MIS System Model No. NWPIMP (NewPort Implant Tray w/ Components) NWP2INSTP (NewPort Instrument Tray w/ Components) The NewPort System is intended to be used as a temporary or permanent posterior, non-cervical implant to correct spinal disorders and provide stabilization of the spine to permit the biological process of spinal fusions to occur.
Integra LifeSciences is recalling the Integra NewPort MIS System because there is a possibility that components from the demonstration set may have been mixed with the NewPort MIS pedicle screw system components used in surgery.
| Attribute | Value |
|---|---|
| Agency | U.S. Food and Drug Administration |
| Severity class | Moderate (Class II) |
| Status | Terminated |
| Recall number | Z-2182-2014 |
| Date reported | August 20, 2014 |
| Date initiated | June 27, 2014 |
| Recalling firm | Integra LifeSciences Corp. |
| Firm location | Plainsboro, NJ |
| Affected scope | 4 units |
| Distribution | US Distribution in TX only. |
Profile values are sourced directly from the official FDA Devices enforcement record. Source: U.S. Food and Drug Administration.
What to do with this recall
Match your product against the recall record, then act on the agency remedy.
This page summarizes the official FDA Devices record for research and awareness; it is not legal, medical, or safety advice. Verify with the issuing agency before acting.
Other recalls in the same product category, useful for spotting patterns across the same defect class or manufacturer.
· 2026-07-02
· 2026-06-25
· 2026-06-18
GE Medical Systems Information Technologies Inc · 2026-06-03
Medline Industries, LP · 2026-06-03
Compare this recall with Rowenta Recalls Cordless Vacuum Cleaners Due to Risk of Ser… →
Every figure on PlainRecalls is rendered directly from official FDA, CPSC and NHTSA recall records, no number is typed in by an editor. This recall: FDA Devices, reported August 20, 2014. Severity classes follow each agency's own taxonomy (FDA Class I/II/III; CPSC and NHTSA by hazard type), and related-recall context is computed across the full archive. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of July 2026.