FDA Devices recall · Reported August 3, 2016
Possible leaking of No Foam solution from the No Foam Bottle Assembly on the UniCel DxC Synchron Systems.
Beckman Coulter Inc. recalled UniCel DxC Synchron Clinical Systems and UniCel DxC Synchron Access Integrated Clinical S… - a moderate-severity action.
UniCel DxC Synchron Clinical Systems and UniCel DxC Synchron Access Integrated Clinical S… was recalled by Beckman Coulter Inc. in August 3, 2016. Reason: Possible leaking of No Foam solution from the No Foam Bottle Assembly on the UniCel DxC Synchron Systems.. Check the official notice for the remedy. Verify recall #Z-2272-2016 with the FDA Devices before acting.
The recall
Beckman Coulter Inc. issued this moderate-severity FDA Devices recall-Possible leaking of No Foam solution from the No Foam Bottle Assembly on the UniCel DxC Synchron Systems..
Sourced from official FDA Devices enforcement records. Verify recall #Z-2272-2016 with the agency before acting. Full product description, hazard, remedy, and related recalls are below.
This FDA Devices action (record #Z-2272-2016) was formally reported on August 3, 2016, with the manufacturer initiating the action on April 22, 2014. It is classified under Moderate severity (Class II), with a current status of Terminated. Beckman Coulter Inc. is listed as the recalling firm, operating out of Brea, CA. Federal records list the affected scope as 3,540 units total (1,067 units in US).
The documented reason for this recall is: Possible leaking of No Foam solution from the No Foam Bottle Assembly on the UniCel DxC Synchron Systems. Distribution data in the federal record shows the product reached: Worldwide Distribution -- United Arab Emirates, Angola, Australia, Belgium, Bulgaria, Canada, Switzerland, China, Colombia, Costa Rica , Czech Republic, Germany, Denmark, Egypt, Eritrea, Spain, Finland, France, United K…. Distribution scope directly affects the consumer exposure window and determines whether a recall remains regional or escalates into a nationwide advisory.
Within the same product category the archive holds 6 closely related recalls, 3 from FDA Devices - clustering in a narrow category often points to a systemic quality-control or supplier issue rather than a one-off defect. Always verify the recall number against the official agency record before acting.
Where this recall sits in its category - 40,322 medical devices recalls on record
Of 101,704 recalls in the database, 24,878 are high severity, 72,426 moderate, and 4,400 low. This recall is classified moderate severity.
Counts reflect market size and reporting activity, not inherent danger, we do not rank products by risk from raw recall volume.
Severity
Moderate
Affected scope
3,540 units total (1,067 units in US)
Related Recalls
6
3 from same agency
UniCel DxC Synchron Clinical Systems and UniCel DxC Synchron Access Integrated Clinical Systems The affected part is Part number 70300. Part number 970300 is used to transfer No Foam Solution from the No Foam Bottle to the Waste B canister and the Waste Manifold on the DxC Hydro System. Catalog No. UniCel DxC 800 Synchron Clinical Systems UniCel DxC 600 Synchron Clinical Systems UniCel DxC 600i Synchron Access Integrated Clinical Systems UniCel DxC 880i Synchron Access Integrated Clinical Systems UniCel DxC 660i Synchron Access Integrated Clinical Systems Product Labeling Reference No. A93719 For the in vitro determination of a variety of general chemistries, therapeutic drugs, and other chemistries.
Possible leaking of No Foam solution from the No Foam Bottle Assembly on the UniCel DxC Synchron Systems.
| Attribute | Value |
|---|---|
| Agency | U.S. Food and Drug Administration |
| Severity class | Moderate (Class II) |
| Status | Terminated |
| Recall number | Z-2272-2016 |
| Date reported | August 3, 2016 |
| Date initiated | April 22, 2014 |
| Recalling firm | Beckman Coulter Inc. |
| Firm location | Brea, CA |
| Affected scope | 3,540 units total (1,067 units in US) |
| Distribution | Worldwide Distribution -- United Arab Emirates, Angola, Australia, Belgium, Bulgaria, Canada, Switzerland, China, Colombia, Costa Rica , Czech Republic, Germany, Denmark, Egypt, Eritrea, Spain, Finland, France, United Kingdom, Greece, Guat… |
Profile values are sourced directly from the official FDA Devices enforcement record. Source: U.S. Food and Drug Administration.
What to do with this recall
Match your product against the recall record, then act on the agency remedy.
This page summarizes the official FDA Devices record for research and awareness; it is not legal, medical, or safety advice. Verify with the issuing agency before acting.
Other recalls in the same product category, useful for spotting patterns across the same defect class or manufacturer.
· 2026-07-02
· 2026-06-25
· 2026-06-18
GE Medical Systems Information Technologies Inc · 2026-06-03
Medline Industries, LP · 2026-06-03
Compare this recall with Rowenta Recalls Cordless Vacuum Cleaners Due to Risk of Ser… →
Every figure on PlainRecalls is rendered directly from official FDA, CPSC and NHTSA recall records, no number is typed in by an editor. This recall: FDA Devices, reported August 3, 2016. Severity classes follow each agency's own taxonomy (FDA Class I/II/III; CPSC and NHTSA by hazard type), and related-recall context is computed across the full archive. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of July 2026.