Severity
Moderate
CPSC recall · Reported September 2, 2004
The SCUBA BC bladder can have a slow leak because of imperfections within the machining of the stainless air barrel of their inflators. This can cause unexpected buoyancy problems…
Halcyon Manufacturing, of High Springs, Fla. recalled Halcyon is recalling all stainless steel power inflators. They have a stainless steel ora… - a moderate-severity action.
CPSC, Halcyon Manufacturing Announce Recall of SCUBA BC Inflators was recalled by Halcyon Manufacturing, of High Springs, Fla. in September 2, 2004. Reason: The SCUBA BC bladder can have a slow leak because of imperfections within the machining of the stainless air …. Remedy: Consumers should stop using these BCs immediately and contact Halcyon for information on …. Verify recall #04209 with the CPSC before acting.
The recall
Halcyon Manufacturing, of High Springs, Fla. issued this moderate-severity CPSC recall-The SCUBA BC bladder can have a slow leak because of imperfections within the machining of the stainless air ….
Sourced from official CPSC enforcement records. Verify recall #04209 with the agency before acting. Full product description, hazard, remedy, and related recalls are below.
This CPSC action (record #04209) was formally reported on September 2, 2004. It is classified under Moderate severity, with a current status of Active. Halcyon Manufacturing, of High Springs, Fla. is listed as the recalling firm. Federal records list the affected scope as About 4,000.
The documented reason for this recall is: The SCUBA BC bladder can have a slow leak because of imperfections within the machining of the stainless air barrel of their inflators. This can cause unexpected buoyancy problems with divers, possibly resulting in deco… Distribution information was not included in the agency filing, so consumers should assume broad potential exposure until the firm publishes point-of-sale details. The remedy documented by the agency is: Consumers should stop using these BCs immediately and contact Halcyon for information on receiving a free repair. - consumers holding this product should act on that instruction rather than relying on general guidance.
Within the same product category the archive holds 6 closely related recalls, 4 from CPSC - clustering in a narrow category often points to a systemic quality-control or supplier issue rather than a one-off defect. Always verify the recall number against the official agency record before acting.
Where this recall sits in its category - 25,126 food recalls on record
Of 101,704 recalls in the database, 24,878 are high severity, 72,426 moderate, and 4,400 low. This recall is classified moderate severity.
Counts reflect market size and reporting activity, not inherent danger, we do not rank products by risk from raw recall volume.
Severity
Moderate
Affected scope
About 4,000
Related Recalls
6
4 from same agency
Halcyon is recalling all stainless steel power inflators. They have a stainless steel oral and power inflate button. Inflators made of plastic are not included in this recall. The repaired inflators have a groove at the base of their retainer nut. The BCs sold with these inflators are black and the Halcyon logo is on the front and collar of the BCs.
The SCUBA BC bladder can have a slow leak because of imperfections within the machining of the stainless air barrel of their inflators. This can cause unexpected buoyancy problems with divers, possibly resulting in decompression sickness.
Consumers should stop using these BCs immediately and contact Halcyon for information on receiving a free repair.
| Attribute | Value |
|---|---|
| Agency | U.S. Consumer Product Safety Commission |
| Severity class | Moderate |
| Status | Active |
| Recall number | 04209 |
| Date reported | September 2, 2004 |
| Date initiated | September 2, 2004 |
| Recalling firm | Halcyon Manufacturing, of High Springs, Fla. |
| Affected scope | About 4,000 |
| Distribution | Not disclosed |
| Official source | CPSC notice → |
Profile values are sourced directly from the official CPSC enforcement record. Source: U.S. Consumer Product Safety Commission.
What to do with this recall
Consumers should stop using these BCs immediately and contact Halcyon for information on receiving a free repair.
This page summarizes the official CPSC record for research and awareness; it is not legal, medical, or safety advice. Verify with the issuing agency before acting.
Other recalls in the same product category, useful for spotting patterns across the same defect class or manufacturer.
· 2026-07-02
Lesonic Technology Co., Ltd., dba Small Fish, of China · 2026-06-25
· 2026-06-18
· 2026-06-11
Legacy Bakehouse LLC · 2026-06-03
Compare this recall with Conair Recalls Over One Million Cuisinart Grill Brushes Due… →
Every figure on PlainRecalls is rendered directly from official FDA, CPSC and NHTSA recall records, no number is typed in by an editor. This recall: CPSC, reported September 2, 2004. Severity classes follow each agency's own taxonomy (FDA Class I/II/III; CPSC and NHTSA by hazard type), and related-recall context is computed across the full archive. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of July 2026.