Severity
Moderate
CPSC recall · Reported September 16, 2020
The recalled portable generators can leak fuel, posing a fire and burn hazard.
The CPSC recalled This recall involves Westinghouse WGen5300DFv Dual Fuel Portable Generators and Westingho… - a moderate-severity action.
MWE Investments Recalls Westinghouse Portable Generators Due to Fire Hazard was recalled and listed by the CPSC in September 16, 2020. Reason: The recalled portable generators can leak fuel, posing a fire and burn hazard.. Remedy: Consumers should immediately stop using the recalled generators and contact MWE Investmen…. Verify recall #20185 with the CPSC before acting.
The recall
issued this moderate-severity CPSC recall-The recalled portable generators can leak fuel, posing a fire and burn hazard..
Sourced from official CPSC enforcement records. Verify recall #20185 with the agency before acting. Full product description, hazard, remedy, and related recalls are below.
This CPSC action (record #20185) was formally reported on September 16, 2020. It is classified under Moderate severity, with a current status of Active. The recalling firm is not specified in the federal record. Federal records list the affected scope as About 7,500.
The documented reason for this recall is: The recalled portable generators can leak fuel, posing a fire and burn hazard. Distribution information was not included in the agency filing, so consumers should assume broad potential exposure until the firm publishes point-of-sale details. The remedy documented by the agency is: Consumers should immediately stop using the recalled generators and contact MWE Investments to arrange for a free repair. - consumers holding this product should act on that instruction rather than relying on general guidance.
Within the same product category the archive holds 6 closely related recalls, 6 from CPSC - clustering in a narrow category often points to a systemic quality-control or supplier issue rather than a one-off defect. Always verify the recall number against the official agency record before acting.
Where this recall sits in its category - 3,056 household products recalls on record
Of 101,704 recalls in the database, 24,878 are high severity, 72,426 moderate, and 4,400 low. This recall is classified moderate severity.
Counts reflect market size and reporting activity, not inherent danger, we do not rank products by risk from raw recall volume.
Severity
Moderate
Affected scope
About 7,500
Related Recalls
6
6 from same agency
This recall involves Westinghouse WGen5300DFv Dual Fuel Portable Generators and Westinghouse iGen4500DF Dual Fuel Inverter Portable Generators with manufacture dates from October 2019 through December 2019. The dual fuel generators can run on gasoline or propane. The WGen5300DFv has a bright blue and black metal exterior and has "Westinghouse" and "WGen5300DFv" printed in white lettering on the control panel on the side of the generator. The generator has a fold down handle and wheels for portability. The generator measures about 23.3 inches long by 20 inches wide inches by 19.29 inches tall without its wheel kit. It weighs about 129 pounds. The iGen4500DF has a bright blue plastic cover and has "Westinghouse iGen4500DF" printed in white lettering on both side panels. The generator measures about 29.7 inches long by 19.7 wide inches by 22 inches tall. It weighs about 105 pounds. Affected units will have one of the following serial numbers, which can be found on the unit's back panel (the "x" fields are specific to individual units): 04511A1019xxxxxxxxx 04511A1219xxxxxxxxx 5311A1219xxxxxxxxx
The recalled portable generators can leak fuel, posing a fire and burn hazard.
Consumers should immediately stop using the recalled generators and contact MWE Investments to arrange for a free repair.
| Attribute | Value |
|---|---|
| Agency | U.S. Consumer Product Safety Commission |
| Severity class | Moderate |
| Status | Active |
| Recall number | 20185 |
| Date reported | September 16, 2020 |
| Date initiated | September 16, 2020 |
| Recalling firm | Not disclosed |
| Affected scope | About 7,500 |
| Distribution | Not disclosed |
| Official source | CPSC notice → |
Profile values are sourced directly from the official CPSC enforcement record. Source: U.S. Consumer Product Safety Commission.
What to do with this recall
Consumers should immediately stop using the recalled generators and contact MWE Investments to arrange for a free repair.
This page summarizes the official CPSC record for research and awareness; it is not legal, medical, or safety advice. Verify with the issuing agency before acting.
Other recalls in the same product category, useful for spotting patterns across the same defect class or manufacturer.
Cooper Lighting, LLC, of Peachtree City, Georgia · 2026-07-02
· 2026-07-02
· 2026-07-02
· 2026-06-25
· 2026-06-25
Compare this recall with Cooper Lighting Recalls Metalux Optimized High Bay LED Ligh… →
Every figure on PlainRecalls is rendered directly from official FDA, CPSC and NHTSA recall records, no number is typed in by an editor. This recall: CPSC, reported September 16, 2020. Severity classes follow each agency's own taxonomy (FDA Class I/II/III; CPSC and NHTSA by hazard type), and related-recall context is computed across the full archive. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of July 2026.